Resumo do Conteúdo

Página 1 - MONITOR AFx

MONITOR AFx™ V3.30 LCD Keypad User's Guide

Página 2

2 MONITOR AFx™ v3.3 LCD Keypad User's Guide 500-9030v3.3 General Concepts Seamlessly Integrated Security MONITOR AFx™ systems provide a seamles

Página 3 - Contents

500-9030v3.3 Welcome Alarm Status Admin Reference 3 Guard Tours Through the MONITOR AFx™ Director software, the routes taken by Guards can be initia

Página 4 - Also See (Related Documents)

4 MONITOR AFx™ v3.3 LCD Keypad User's Guide 500-9030v3.3 System Software and Licensing The MONITOR AFx™ Director Software The MONITOR AFx Dir

Página 5

500-9030v3.3 Welcome Alarm Status Admin Reference 5 Dual-Language Framework The MONITOR AFx system provides a framework for dual-language support, a

Página 6 - FCC Regulations

6 MONITOR AFx™ v3.3 LCD Keypad User's Guide 500-9030v3.3 Overview of Tasks (What can be Done from Where) Adjusting the 'Closing' Tim

Página 7 - UL Listed Systems

500-9030v3.3 Welcome Alarm Status Admin Reference 7 Avoiding False Alarms No matter how full-featured, and reliable a security system is, a number o

Página 8

8 MONITOR AFx™ v3.3 LCD Keypad User's Guide 500-9030v3.3 1 2 34 5 67 8 90▲▲▲X✴'- #ABC DEFGHI JKL MNOPRS TUV WXYZ_Q The MONITOR AFx LCD key

Página 9 - Welcome

500-9030v3.3 Welcome Alarm Status Admin Reference 9 If the door is unlocked, access is not controlled (simply open the door to enter the area). Co

Página 10 - General Concepts

10 MONITOR AFx™ v3.3 LCD Keypad User's Guide 500-9030v3.3 If You Are Being Forced to Enter A duress (panic) alarm is triggered when you enter y

Página 11 - Special-Use Features

500-9030v3.3 Welcome Alarm Status Admin Reference 11 Time: This allows changing the time and/or date for a system panel. Verify: This allows a per

Página 13 - Dual-Language Framework

12 MONITOR AFx™ v3.3 LCD Keypad User's Guide 500-9030v3.3 

Página 14 - Overview of Tasks

500-9030v3.3 Welcome Alarm Status Admin Reference 13 Alarms, Arming and Disarming

Página 15 - Avoiding False Alarms

14 MONITOR AFx™ v3.3 LCD Keypad User's Guide 500-9030v3.3 Alarm Monitoring Features Depending on how the system is set up, specific alarms may

Página 16 - The MONITOR AFx™ LCD Keypad

500-9030v3.3 Welcome Alarm Status Admin Reference 15 Sirens Conventional Siren Fire Alarm: Intermittent Tone (see previous details). Burglar Alarm

Página 17 - Common Tasks

16 MONITOR AFx™ v3.3 LCD Keypad User's Guide 500-9030v3.3 Using the Emergency Keys There are three emergency keys that will activate an emergen

Página 18 - Overview of Screens (Topics)

500-9030v3.3 Welcome Alarm Status Admin Reference 17 Suspending Schedules for an Area or Areas A schedule can be blocked altogether if you do not wa

Página 19 - Keypad Entry Basics

18 MONITOR AFx™ v3.3 LCD Keypad User's Guide 500-9030v3.3 7) Select View to view points that are currently bypassed or not Ok. At this time t

Página 20 - 500-9030v3.3

500-9030v3.3 Welcome Alarm Status Admin Reference 19 Checking Status and Controlling Items

Página 21 - Alarms, Arming

20 MONITOR AFx™ v3.3 LCD Keypad User's Guide 500-9030v3.3 Status and Control Features Using an LCD keypad, you can: • Check the status of vario

Página 22 - Audible Keypad Tones

500-9030v3.3 Welcome Alarm Status Admin Reference 21 Checking the Status of Sensors (Points) and Areas The Points-status feature allows checking the

Página 23 - Silencing a False Alarm

500-9030v3.3 (August 2001) © 2001 CSG Security Inc. / Sécurité CSG Inc. i About This Guide...

Página 24 - Scheduled Closing Time

22 MONITOR AFx™ v3.3 LCD Keypad User's Guide 500-9030v3.3 Checking Status or Controlling Readers or Doors The Door status screens allow persons

Página 25 - Present Arming-Level

500-9030v3.3 Welcome Alarm Status Admin Reference 23 Checking the Status of a Condominium Unit (Condominium/Multi-Tenant Keypad) For systems that i

Página 26

24 MONITOR AFx™ v3.3 LCD Keypad User's Guide 500-9030v3.3 

Página 27 - Checking Status

500-9030v3.3 Welcome Alarm Status Admin Reference 25 Administration and Maintenance Tasks

Página 28 - Checking the System Status

26 MONITOR AFx™ v3.3 LCD Keypad User's Guide 500-9030v3.3 Changing Your Own PIN The person who is logged in can change their PIN number at any

Página 29 - Bypassing a Faulty Sensor

500-9030v3.3 Welcome Alarm Status Admin Reference 27 More: Provides access to additional screens. Name: Use the keypad to enter the user's n

Página 30 - Readers or Doors

28 MONITOR AFx™ v3.3 LCD Keypad User's Guide 500-9030v3.3 PIN: This allows setting or changing the Personal ID Number for this user. (You&apo

Página 31 - Admin Reference

500-9030v3.3 Welcome Alarm Status Admin Reference 29 5) Then, select Yes to delete the user, or select Cancel if you changed your mind. 6) To retur

Página 32

30 MONITOR AFx™ v3.3 LCD Keypad User's Guide 500-9030v3.3 Printing the History Log If your system includes a printer-capable module (such as HS

Página 33 - Administration

500-9030v3.3 Welcome Alarm Status Admin Reference 31 Testing Monitored Sensors (Performing a Walk Test) A Walk Test allows you to test specific s

Página 34 - Adding a User to the System

ii MONITOR AFx™ v3.3 LCD Keypad User's Guide 500-9030v3.3 About This Guide This guide provides details on performingvarious tasks in a MONITOR

Página 35

32 MONITOR AFx™ v3.3 LCD Keypad User's Guide 500-9030v3.3 Testing Panic Buttons (Performing a Holdup Test) A Holdup Test allows you to test &q

Página 36 - Deleting a User

500-9030v3.3 Welcome Alarm Status Admin Reference 33 Reference Topics

Página 37 - Viewing the History

34 MONITOR AFx™ v3.3 LCD Keypad User's Guide 500-9030v3.3 Your MONITOR AFx system has information specific to your installation. This informat

Página 38 - Language

500-9030v3.3 Welcome Alarm Status Admin Reference 35 System Configuration Aspects: Programmed Entry and Exit Delays: Entry Delay:_______ Ex

Página 39 - (Performing a Walk Test)

36 MONITOR AFx™ v3.3 LCD Keypad User's Guide 500-9030v3.3 Schedules for User Access and System Automation About Schedules Schedules are customi

Página 40 - Testing Sirens (System Test)

500-9030v3.3 Welcome Alarm Status Admin Reference 37 Schedule Int Start Stop Sun Mon Tue Wed Thu Fri Sat __ _________ 1 2 3 4 5 6 _____ _____ __

Página 41 - Reference

38 MONITOR AFx™ v3.3 LCD Keypad User's Guide 500-9030v3.3 Holidays and Time-Change Dates About Holidays Holidays are defined dates that: • Aut

Página 42 - Basic Settings

500-9030v3.3 Welcome Alarm Status Admin Reference 39 Photocopy and/or fill in the holiday list for your MONITOR AFx system: # Holiday (Name, Date

Página 43 - Function Key Reference

40 MONITOR AFx™ v3.3 LCD Keypad User's Guide 500-9030v3.3 Authority Levels (Profiles) for Users About Authority Levels Authorities determine th

Página 44

500-9030v3.3 Welcome Alarm Status Admin Reference 41 Authority Level #, Name: User Ranges: Auth. Ranges: Area Profile: Sched: Areas: Silence Al

Página 45

500-9030v3.3 (August 2001) © 2001 CSG Security Inc. / Sécurité CSG Inc. iii Industry Canada Notice of Limitations Notice: The

Página 46 - About Holidays

42 MONITOR AFx™ v3.3 LCD Keypad User's Guide 500-9030v3.3 No fire detection system should be considered 100 percent foolproof. This fire alarm

Página 47 - Welcome Alarm Status Admin

500-9030v3.3 Welcome Alarm Status Admin Reference 43 • If you live in a high-rise building, use the stairs — never the elevator — in case of fire.

Página 48

44 MONITOR AFx™ v3.3 LCD Keypad User's Guide 500-9030v3.3 MONITOR AFx™ Arming Station (option) The optional MONITOR AFx Arming Station allows

Página 49

500-9030v3.3 Welcome Alarm Status Admin Reference 45 MONITOR AFx Arming Station LEDs The optional MONITOR AFx Arming Station has three LEDs to ind

Página 50 - Practicing Fire Safety

46 MONITOR AFx™ v3.3 LCD Keypad User's Guide 500-9030v3.3 MONITOR AFx Wireless Keypad (option) The optional MONITOR AFx Wireless Handheld Keyp

Página 51 - Messages for young children

500-9030v3.3 Welcome Alarm Status Admin Reference 47 LCD Error Messages The following section contains a comprehensive list of error messages that

Página 52 - Arming Station Reference

48 MONITOR AFx™ v3.3 LCD Keypad User's Guide 500-9030v3.3 2000 (Year-2000 compliance)... ii Access...

Página 53 - MONITOR AFx Arming Station

500-9030v3.3 Welcome Alarm Status Admin Reference 49 Overview of Tasks (What can be Done from Where) ...

Página 55 - System Status Trouble

iv MONITOR AFx™ v3.3 LCD Keypad User's Guide 500-9030v3.3 FCC Class A Digital Device Notice This device complies with Part 15 of the FCC Rule

Página 56

500-9030v3.3 (August 2001) © 2001 CSG Security Inc. / Sécurité CSG Inc. v If the terminal equipment (MONITOR AFx)causes harm to

Página 57

vi MONITOR AFx™ v3.3 LCD Keypad User's Guide 500-9030v3.3 

Página 58

500-9030v3.3 Welcome Alarm Status Admin Reference 1 Welcome

Comentários a estes Manuais